Synonym |
Z-GP-AMC |
Species |
Human |
Protein Accession |
P15491 |
Purity |
≥ 95% |
Endotoxin Level |
< 1.0 EU per μg |
Biological Activity |
Not specified |
Expression System |
E. coli |
Fusion Tag |
His-tag |
Predicted Molecular Mass |
27.8 kDa |
Formulation |
Supplied as a lyophilized powder |
Reconstitution |
Reconstitute in PBS |
Storage & Stability |
Store at -20°C upon receipt, stable for up to 6 months |
FAQ
What is Z-GP-AMC, and what are its primary applications in research and industry?
Z-GP-AMC is a
synthetic compound widely used in biochemical research and industry for its role as a substrate for
protease enzymes, particularly in studying proteolytic activity. It stands for
N-benzyloxycarbonyl-glycyl-prolyl-7-amido-4-methylcoumarin. This compound is recognized for its ability
to release a fluorescent signal upon enzymatic cleavage, which makes it an invaluable tool in assays
where detecting enzyme activity is crucial. Proteases, or proteolytic enzymes, play vital roles in
numerous biological processes, including digestion, immune response, cell signaling, and the cell
lifecycle. Consequently, Z-GP-AMC's ability to serve as a model substrate for these enzymes allows
researchers to investigate and quantify the proteolytic activity under various conditions, aiding in the
understanding of complex biological systems.
In academic and industrial research, Z-GP-AMC finds
applications across a breadth of fields. It is used extensively in drug development to screen for
potential enzyme inhibitors or activators, which could lead to new therapeutic agents. For instance,
researchers aiming to develop treatments for diseases where protease activity is implicated, such as
cancer, Alzheimer’s, or arthritis, utilize this substrate to identify compounds that could modulate
protease activity effectively. Additionally, in the realm of diagnostics, Z-GP-AMC is employed in assays
designed to measure protease activity levels in various biological samples, providing insights into
disease mechanisms and progression.
Moreover, Z-GP-AMC's utility extends to quality control
processes in the biotechnology and pharmaceutical industries. Enzyme preparations are tested for
activity and stability using substrates like Z-GP-AMC to ensure consistency and effectiveness before
they are employed in production settings or therapeutic applications. As the biotechnological landscape
continues to expand and evolve, the importance of reliable, sensitive, and accurate tools like Z-GP-AMC
becomes increasingly evident, establishing it as a cornerstone in both fundamental research and
practical applications.
How does Z-GP-AMC function in a typical laboratory assay, and what are
the key considerations for its use?
Z-GP-AMC operates in a laboratory assay as a fluorescent
substrate that provides a quantifiable signal once it is cleaved by a specific protease. The design of
Z-GP-AMC allows it to interact specifically with the protease of interest. Upon cleavage of the amide
bond between the proline and the amido-4-methylcoumarin components, the AMC moiety is released,
producing a fluorescent signal. This fluorescence can be measured using spectrophotometric equipment,
giving an indication of the enzymatic activity present in the sample. The intensity of the fluorescence
correlates with the amount of substrate cleaved, thus, allowing for quantitative analysis of enzyme
kinetics, inhibitor studies, and other related experiments.
When using Z-GP-AMC in laboratory
assays, several key considerations must be addressed to ensure accurate, reliable results. Firstly, the
choice of enzyme to substrate concentration must be optimized. An excess of substrate relative to enzyme
is generally preferred to maintain pseudo-first-order kinetics, which simplifies data interpretation.
It’s also essential to confirm the specificity of the protease being studied. Many proteases have
overlapping substrate specificities, and cross-reactivity could lead to misinterpretation of results if
unaccounted for.
Fluorescent assays are highly sensitive to environmental conditions, so
maintaining a constant temperature and appropriate pH is crucial. The buffer system selected should not
interfere with enzyme activity or fluorescent measurement. Moreover, the sensitivity of fluorescence
means that precautions such as avoiding ambient light exposure and using black microplates or cuvettes
are recommended to minimize background noise.
Additionally, calibrating the assay with known
standards of AMC can improve quantitative accuracy, especially when comparing results across different
experiments or conditions. The choice of equipment, such as a fluorometer capable of detecting the
specific excitation and emission wavelengths of AMC, further enhances the reliability of the assay.
Finally, researchers must consider potential inhibitors or enhancers present in the assay buffer or
sample matrix, which could affect enzyme activity. Careful experimental design and awareness of these
factors will maximize the effectiveness of Z-GP-AMC as a research tool.
What are the benefits of
using Z-GP-AMC compared to other protease substrates?
The use of Z-GP-AMC in protease assays
provides several advantages over other protease substrates, attributes that make it highly favored in
both research and industrial settings. One of the most notable benefits is its high sensitivity due to
the fluorescent nature of the 7-amido-4-methylcoumarin moiety. Upon cleavage by the target protease,
Z-GP-AMC liberates AMC, which exhibits strong fluorescent properties. This allows for detection of
protease activity at lower concentrations than might be possible with colorimetric or turbidimetric
substrates, thus allowing for early detection and monitoring of enzyme kinetics or inhibition at lower
enzyme concentrations.
Another benefit lies in the specificity of Z-GP-AMC, particularly when
paired with well-characterized proteases. The peptide structure, consisting of
N-benzyloxycarbonyl-glycyl-prolyl, allows selective binding and cleavage by certain proteases, offering
researchers the ability to target specific enzymes for precise biochemical analysis. This specificity
can be particularly advantageous when studying proteases that overlap in substrate preference, such as
those involved in complex cellular pathways or processes.
In terms of assay convenience, Z-GP-AMC
is straightforward to use, with assays typically requiring only standard laboratory equipment like a
fluorometer, black multiwell plates, and a basic understanding of enzyme kinetics. This accessibility is
a stark contrast to some traditional substrates, which might necessitate more complex detection methods
requiring advanced skill sets or specialized devices.
Furthermore, the stability of Z-GP-AMC
under a variety of assay conditions is a pragmatic benefit. It tends to remain stable in different
buffer conditions and within a broad pH range, assuring researchers that the substrate will not degrade
or denature under typical experimental setups. In comparison, some natural substrates might require
specific storage conditions or time-sensitive handling to maintain activity and
reliability.
Finally, the quantitative capability of Z-GP-AMC coupled with its fluorescent
outcome enables the real-time monitoring of protease activity. This dynamic range allows for detailed
kinetic studies, providing deeper insight into enzyme activity, inhibition constants, and reaction
mechanisms. When assessing these factors collectively, Z-GP-AMC’s benefits in terms of sensitivity,
specificity, ease of use, stability, and quantitative capacity distinctly position it as a superior
substrate choice for protease research.
What are the potential limitations or challenges
associated with using Z-GP-AMC in assays?
While Z-GP-AMC offers numerous advantages, some
limitations and challenges may arise when utilizing it (or any fluorescent substrate) in assays.
Understanding these potential constraints is necessary to mitigate them during experimental design for
optimal results.
One primary limitation involves protease specificity. Z-GP-AMC has broad
applicability, but the specificity of the substrate for a particular protease can sometimes lead to
cross-reactivity, particularly in complex samples containing multiple proteolytic activities. This lack
of absolute specificity demands that investigators meticulously confirm the presence and purity of the
protease being analyzed to ensure accurate attribution of observed activity specifically to the enzyme
of interest.
The assays involving fluorescent substrates like Z-GP-AMC also require appropriate
instrumentation that can detect fluorescence at specific wavelengths (AMC has excitation and emission
maxima typically near 350 nm and 440 nm, respectively). Laboratories lacking such equipment might face
barriers in effectively implementing or adapting these substrates in experimental workflows.
Additionally, the expense of acquiring or maintaining such fluorescent detection equipment might be a
consideration for some research facilities, especially those with limited funding.
Environmental
sensitivity of fluorescence-based assays is another noteworthy challenge. Fluorescent signals can be
influenced by extraneous factors such as ambient light, which necessitates careful control of
experimental conditions to avoid background noise or signal interference. Using opaque or black plates
can mitigate some of these issues, but awareness of potential interference remains crucial in
experimental setup and data analysis.
Furthermore, while Z-GP-AMC is stable under most
conditions, the hydrolytic stability of other components in the reaction mixture, such as the protease
itself or potential inhibitors, must be accounted for since they could significantly affect the accuracy
of the kinetic measurements.
Lastly, interpreting data from fluorescent substrates can be complex
when distinguishing between true enzymatic activity and non-specific interactions. This necessitates a
thorough understanding of the enzyme-substrate interaction and proper assay controls, such as substrate
blanks and enzyme-free controls, to distinguish the fluorescent response elicited by specific
proteolytic action from potential artifact readings.
Overall, while Z-GP-AMC is a versatile and
effective tool in protease activity assays, awareness and strategic planning around potential challenges
are essential to leverage its full potential and achieve reliable, reproducible data
outcomes.
What safety considerations should be noted when working with Z-GP-AMC in the
laboratory?
Handling Z-GP-AMC in the laboratory requires adherence to standard safety protocols
to ensure both personal safety and experimental integrity. Like many chemical reagents used in
laboratory settings, it is crucial to operate with an awareness of the potential hazards and adhere to
safety procedures to mitigate any risks involved.
Firstly, Z-GP-AMC, as with any chemical
substrate, should be regarded as potentially hazardous. It is essential to consult the material safety
data sheet (MSDS) or safety data sheet (SDS) for detailed information on handling, storage, and
emergency measures. This document provides comprehensive insights into the chemical’s properties,
potential hazards, and recommended safety precautions, thus serving as an important resource to guide
safe use and prevent accidental exposure.
Wear appropriate personal protective equipment (PPE)
when working with Z-GP-AMC, which typically includes lab coats, gloves, and safety goggles. This
minimizes the risk of skin contact, ingestion, or eye irritation, which are precautionary measures
standard for most chemical experiments. When possible, handling should be conducted inside a fume hood
or a well-ventilated area to avoid inhalation of any dust or fumes that may be generated.
In
terms of storage, Z-GP-AMC should be kept under recommended conditions, often including a cool, dry
place away from direct sunlight or heat sources, which could degrade the chemical. Proper labeling and
segregation from incompatible substances are also important to ensure stability and maintain the
compound's reactive properties.
Additionally, ensure all waste is disposed of according to local
regulations and institutional guidelines for hazardous chemical disposal. This prevents environmental
contamination and reduces risk within the laboratory setting. Laboratories should have spill kits and
first aid measures in place, accompanied by training for personnel to respond effectively in the event
of accidental release or exposure.
Beyond personal safety, preserving the integrity of Z-GP-AMC
implies maintaining aseptic techniques to avoid contamination, which could interfere with experimental
outcomes. Adhering to these safety principles not only safeguards laboratory personnel but also ensures
the reliability and reproducibility of biochemical assays using Z-GP-AMC, ultimately contributing to a
safe, productive research environment.